May occur in Review runs during optimisation of a run when using MPR(X) merge.
The causes are as follows:-
- Nesting type is set to MPR(X) Merge
- Some of the part MPR(X) files are external and not set to the same measurement mode as the Optimising program.
For example: Optimising program is set to Millimetres and one or more external MPR(X) files are set to Inches.
The measurement mode of the existing part MPR(X) files must match the Optimising program measurement mode.
Check the external MPR(X) files.
33113 |