Occurs when optimising a part list or product requirements list
- If the optimising parameters: 'Information box for priority' and, Max open parts are both set the optimisation cannot proceed.
These two parameters cannot be both be set as they often conflict
Note - if the optimising parameter for the number of open parts is set but is less than the number of part types (sizes) for a material in the part list the open parts parameter does not apply.
- The error is also shown if part priorities are set and there are more part sizes than the max open parts and there is more than one board size and the override board loading sequence parameter is NOT set.
There is a conflict between these parameters.
The error occurs because with more than one board size patterns are grouped by board size which means priority sequence can be invalidated.
(If override board loading sequence is set this error is not reported as it may be possible to optimise the data and obey part priorities since the final solution is not be sorted by board number).
Check the optimiser parameter settings
38037 |