Transfer to SCM Seziona - set up

 

How to set up the system to transfer data to an SCM saw - Seziona

 

This is for the saw model: Seziona

 

System parameters

 

- Set Create data for to include: 3. This ensures that data for cutting dimensions is created

 

Saw Transfer parameters

 

- Set up an entry for the saw in the list. The parameter values to set are as follows.

 

Transfer mode - set to: 15 - SCM Seziona

 

Path for saw data - any directory.

 

The saw transfer process generates ‘.prg’ and ‘.lst’ files  sub-directories named ‘Prg’ and ‘Lst’ on this path.

 

Buffered - When this option is set previous files are NOT deleted

 

Saw parameters

 

Set Saw model number to: 62 SCM Seziona

 

- Refer to the saw supplier for advice on setting the optimising and saw parameters.

 

Label Information

 

The transfer creates the following label information for parts:-

 

Field No.  Part data

1          Part code

2          Material code

3          Part length

4          Part width

5          Information box 1

6          Information box 2

64         Information box 60

 

The label data only includes up to the last configured information box containing data, for example:-

 

[Dati]

NumeroDati=1

1=L0005,EBONY-LAM,1070.000000,904.000000,,,,,,,00001233*,,,,Grained,MED

 

 

See also