How to set up the system to transfer data to an SCM saw - Seziona
This is for the saw model: Seziona
System parameters
- Set Create data for to include: 3. This ensures that data for cutting dimensions is created
Saw Transfer parameters
- Set up an entry for the saw in the list. The parameter values to set are as follows.
Transfer mode - set to: 15 - SCM Seziona
Path for saw data - any directory.
The saw transfer process generates ‘.prg’ and ‘.lst’ files sub-directories named ‘Prg’ and ‘Lst’ on this path.
Buffered - When this option is set previous files are NOT deleted
Saw parameters
Set Saw model number to: 62 SCM Seziona
- Refer to the saw supplier for advice on setting the optimising and saw parameters.
Label Information
The transfer creates the following label information for parts:-
Field No. Part data
1 Part code
2 Material code
3 Part length
4 Part width
5 Information box 1
6 Information box 2
…
…
64 Information box 60
The label data only includes up to the last configured information box containing data, for example:-
[Dati]
NumeroDati=1
1=L0005,EBONY-LAM,1070.000000,904.000000,,,,,,,00001233*,,,,Grained,MED